Flexible reeling cable for energy supply and data transmission. Especially for high and extreme mechanical stress, e.g. torsional stress and high reeling speed up to 270 m/min. For deflection into different planes. Main applications : Ship To Shore cranes (STS), Rail Mounted Gantry cranes (RMG), Ship Unloaders, Stacker Reclaimers and other heavy mobile equipment.
Conductor Flexible stranded plain copper, "FSC" better than DIN EN/IEC 60228 class 5
Insulation
Protective conductor Flexible stranded plain copper, "FSC" better than DIN EN/IEC 60228 class 5, semi-conducting layer
Optical Fiber n x E9/125 µm, n x G50/125 µm, n x G62.5/125 µm or combination of them
Inner sheath Special synthetic rubber compound better than GM1b acc. DIN VDE 0207 part 21
Reinforcement Synthetic threads with very high tensile strength as a protection against twist stress and pressure loads
Outer sheath Heavy duty chlorinated rubber compound 5GM5 acc. DIN VDE 0207 part 21. New special sandwich construction for optimal flexibility , abrasion resistance and heavy load.
RHEYFIRM(RTS) R-(N)TSCGEWTOEUS 3x95+2x50/2+OFE12G62.5/125 6/10 kV I NEXANS I year
Split protective conductor are integrated into two of the three interstices. The optical fiber element is integrated into the third. Length of lay is optimized for the different applications.
Tensile stress of the conductor
staticdynamic
15 N/mm²30 N/mm²
Bending radii
acc. to DIN VDE 0298-3
Tests
alternating/reversed bending test,torsional resistance test, reeling test
Reeling speed
up to 240 m/min(for higher speed please contact us)
Nominal voltageMax. operating voltage in AC systemsMax. operating voltage in DC systems
Uo/UUmVm
1.8/3 kV to 18/30 kV1.2 x U1.8 x U
Test voltage (acc. DIN VDE 0250 part 813)
11 to 45 kV in AC27.5 to 107.5 kV in DC
Current-carrying capacity
acc. DIN VDE 0298-4see PDF-File "Current-carrying capacities / Strombelastbarkeit"
Max. conductor resistance
acc. DIN EN / IEC 60228 class 5see PDF-File "Conductors / Leiter"
Reduction factors
see PDF-File "Correction factors / Umrechnungsfaktoren"
Fibre types
…E9/125…G50/125…G62.5/125
This table describes the colour coding of the different fiber optics.Rings are added for number of fiber over 12
1
2
3
4
5
6
7
8
9
10
11
12
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
13
14
15
16
17
18
19
20
21
22
23
24
1 ring
2 rings
…E9/125ITU-T G.652.DOS2 acc. IEC 60793-2-50ISO/IEC 24072
…G50/125ITU-T G.651OM2 acc. IEC 60793-2-10ISO/IEC 11801
…G62.5/125ITU-T G.651OM1 acc. IEC 60793-2-10ISO/IEC 11801
Geometrical characteristics
Mode field diameter
9.0 ± 0,5 µm
50 ± 3 µm
62.5 ± 3 µm
Core non-circularity
≤ 5.0 %
Cladding diameter
125 ± 2 µm
Cladding non-circularity
≤ 2 %
Coating diameter
245 ± 10 µm
Numerical aperture
-
0.200 ± 0.015
0.275 ± 0.015
Optical characteristics
Attenuation coefficient:@ 850 nm@ 1310 nm@ 1550 nm
≤ 0.5 dB/km≤ 0.4 dB/km
≤ 3.0 dB/km≤ 1.0 dB/km
≤ 3.5 dB/km≤ 1.5 dB/km
Bandwidth:@ 850 nm@ 1300 nm
≥ 600 MHz*km≥ 1200 MHz*km
≥ 200 MHz*km≥ 500 MHz*km
Chromatic Dispersion:1270 - 1340 nm1285 - 1330 nm1550 nm
< 5.0 ps/nm*km< 3.5 ps/nm*km< 18 ps/nm*km
Index of reflaction (IOR):@ 850 nm@ 1300 nm@ 1310 nm@ 1550 nm
1.4671.467
1.496 1.491
1.4677 1.4682
Mechanical characteristics
Strip force (peak)
1.3 ≤ Fpeak strip ≤ 8.9 N
Proof test
690 N/mm²
Test elongation for 1 s
1.0 %