Application
TCX® (C) type is used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. For open decks installation, cables have to be covered against UV rays. TCX® (C) type withstands the IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements.
Design
All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. This cable type is especially designed for installations on passenger ships.
- Conductor:
Bare copper
Stranded class 2
- Insulation:
XLPE (cross linked polyethylene)
- Separator:
Polyester tape
- Armouring:
Bare copper braid with bare copper drain wire
- Outer sheath:
Polyolefin SHF1
Colour: grey
SHF2 on request
Type Approval Certificates
American bureau of Shipping
Bureau Veritas
China Classification Society
Det Norske Veritas
Lloyd's Register of Shipping
Registro Italiano Navale
Core identification
- Core 1 : white
- Core 2 : blue
- Core 3 : red
Double identification: pair and core
Marking
NEXANS 205 TCX (C)* - "voltage" - n** P or T s** mm² - 90 °C - IEC 60332-3-22 - WW/YY** - CE TC+ Metric Marking
* except for 1 pair and 1 triple, the cable marking is TCX(I)
** n = number of pair/triple
** s = cross-section of pair/triple
WW/YY = week and year of manufacturing
|