English Вход Регистрация Каталог продукции Контакты
Глобальный эксперт в кабельных системах

О компании

Продукция и решения

Обслуживание

Работа в Nexans

Новости и пресса

Искать

NF C 33-209 Aluminium cables

Закладка Печать Напишите нам
NF C 33-209 Aluminium cables
Стандарты
Национальные  NF C 11-201; NF C 33-209
Описание

Application

ALUMINIUM NF C 33-209 service bundled conductors are used for tributary networks of power buildings and their internal networks.

Characteristics

The bundled conductor cables have aluminum conductors, insulated with XLPE, they have good durability and thermal resistance.

Some other important cable characteristics are :

  • Ultraviolet radiation resistance,
  • Ozone resistance,
  • High dielectric strength,
  • Light and easy to handle.

Installation

The NF C 11-201 standard´s procedures determine the installation procedures for low voltage overhead lines.

These cables are NOT ALLOWED to be buried, even in conduits.

Marking

  • Neutral :

211 NF C 33-209 211 « manufacturing number », « metric marks » ink printed.

  • Phase 1, 2, 3 :

the identification number is printed and embossed on insulation.

  • Pilot wire n°1 : continuous white line is printed on the insulation
  • Pilot wire n°2 : no marking

Electrical characteristics

  • Rated voltage : 0.6/1 kV
  • Test voltage : 4 kV AC
  • Resistance to voltage surges : 1.2/50µs with a positive or negative polarity and a peak value of 20 kV.

 Наверх
Характеристики
Конструктивные характеристики
Insulation XLPE (chemical)  
Материал жилы Алюминий  
Электрические характеристики
Rated Voltage Uo/U (Um) 0.6/1 kV  
Test voltage 1mn 50Hz 4кВ  

 Наверх
Ваш выбор
Сечение жилы  мм²
Neutral messenger  
Number of cores  
Pilot wires  
Упаковка  
Длина (м)  m
Применить
Сбросить
Результат выборки   18/18
Выбрать все позиции Код Nexans Описание страны Название Сечение жилы (мм²) Neutral messenger Number of cores Pilot wires
10057482 01123130 FR-N1XD4-AR 2x16 +2x1.5 NFC33209 cut to length 16 None 2 2 x 1.5 mm²
10057490 01124090 FR-N1XD4-AR 2x16 NFC33209 coil of 100 m P2km 16 None 2 None
10044008 01123090 FR-N1XD4-AR 2x16 NFC33209 cut to length 16 None 2 None
10057485 01124110 FR-N1XD4-AR 2x25 +2x1.5 C33209 coil of 100 m P1.6km 25 None 2 2 x 1.5 mm²
10057486   To be removed 01124115 FR-N1XD4-AR 2x25 +2x1.5 C33209 coil of 150 m P0.9km 25 None 2 2 x 1.5 mm²
10057487 01123110 FR-N1XD4-AR 2x25 +2x1.5 NFC33209 cut to length 25 None 2 2 x 1.5 mm²
10057493 01124070 FR-N1XD4-AR 2x25 NFC33209 coil of 100 m P1.6km 25 None 2 None
10044010 01123070 FR-N1XD4-AR 2x25 NFC33209 cut to length 25 None 2 None
10057484 01123330 FR-N1XD4-AR 4x16 +2x1.5 NFC33209 cut to length 16 None 4 2 x 1.5 mm²
10057492 01124290 FR-N1XD4-AR 4x16 NFC33209 coil of 100 m P2.8km 16 None 4 None
10044009 01123290 FR-N1XD4-AR 4x16 NFC33209 cut to length 16 None 4 None
10057489 01123310 FR-N1XD4-AR 4x25 +2x1.5 NFC33209 cut to length 25 None 4 2 x 1.5 mm²
10057495 01124270 FR-N1XD4-AR 4x25 NFC33209 coil of 100 m P0.9km 25 None 4 None
10044011 01123270 FR-N1XD4-AR 4x25 NFC33209 cut to length 25 None 4 None
10057499   To be removed 01068264 FR-N1XD9-AR_AD 1x16 +54.6 NFC33209 cut to length 16 54.6 mm² 1 None
10057502 01068260 FR-N1XD9-AR_AD 2x16 +54.6 NFC33209 cut to length 16 54.6 mm² 2 None
10057575 01068253 PHASE TORSADE 1x16AL NFC 33209 cut to length 16 None 1 None
10057474 01068254 PHASE TORSADE 1x25AL NFC 33209 cut to length 25 None 1 None
В избранное

 Наверх
Связанная информация
NF C 33-209 Aluminium cables   AFAQ certification for Bohain and Jeumont (pdf) (282 kB)
Homologation certificates
NF C 33-209 Aluminium cables   Usual packaging for aerial bundled cables NF C 33-209 (40 kB)
Guides
NF C 33-209 Aluminium cables   Installation methods for low voltage overhead lines (174 kB)
Guides
NF C 33-209 Aluminium cables   Connection aluminium bundled conductors with pilot wires (400 kB)

Nexans © все права защищены 2001 - 2012   Legal Notice | Контакты | Карта сайта