LV fire-resistant cables

Закладка Напишите нам

 

Used in residential, public and industrial buildings, fire-resistant cables allow fire alarms, smoke evacuation, lighting, sprinklers, etc. to continue operating during a fire.

 

Rewiring of Duchess Anna Amalia Library (Germany)

 LV fire-resistant cables

 


Продукты Nexans
Название продукта   PDF file
ALSECURE RHEYHALON N2XCH E30-E60*
Wires and cables <1kV/Low smoke & fire resistant

Power Cable

Circuit Integrity 30 - 60* Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to DIN VDE 0472-814

Halogen Free with a better behaviour in case of fire acc. to DIN VDE 0266

 
ALSECURE RHEYHALON N2XCH E90*
Wires and cables <1kV/Low smoke & fire resistant

Power Cable

Circuit Integrity 90 Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to DIN VDE 0472-814

halogen free with improved behaviour in case of fire acc. to DIN VDE 0266

 
ALSECURE RHEYHALON N2XH-O/J E30-E60*
Wires and cables <1kV/Low smoke & fire resistant

Power Cable

Circuit Integrity 30 - 60* Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to DIN VDE 0472-814

halogen free with improved behaviour in case of fire acc. to DIN VDE 0266

 
ALSECURE RHEYHALON N2XH-O/J E90*
Wires and cables <1kV/Low smoke & fire resistant

Power Cable

Circuit Integrity 90 Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to DIN VDE 0472-814

halogenfree with improved behaviour in case of fire acc. to DIN VDE 0266

 
ALSECURE RHEYHALON Security Cable JE-H(ST)H E30*
Wires and cables <1kV/Low smoke & fire resistant

Telecommunication Cable / Fire Alarm Cable

Circuit Integrity 30 Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to IEC 60 331

Halogen Free with a better behaviour in case of fire acc. to DIN VDE 0815

 
ALSECURE RHEYHALON Security Cable JE-H(ST)H E30-E90*
Wires and cables <1kV/Low smoke & fire resistant

Telecommunication Cable / Fire Alarm Cable

Circuit Integrity 30 resp. 90* Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to IEC 60 331

Halogen Free with a better behaviour in case of fire acc. to DIN VDE 0815

 
ALSECURE® PLUS 300/500V
Wires and cables 1kV/Fire resistant cables 1kV
CR1-C1-C2
Uo/U: 300/500V
Halogen free
Fire resistant cables
 
ALSECURE® PLUS 300/500V Multicores
Wires and cables 1kV/Fire resistant cables 1kV
CR1-C1-C2 F2-FR2-PH60
Fire Resistant Cables
 
ALSECURE® PLUS A 300/500V
Wires and cables 1kV/Fire resistant cables 1kV
CR1-C1-C2
Fire Resistant Cables
 
ALSECURE® PLUS A 300/500V Multicores
Wires and cables 1kV/Fire resistant cables 1kV
CR1-C1-C2
Fire Resistant Cables
 
ALSECURE® PLUS TEL 100/170 V
Wires and cables 1kV/Fire resistant cables 1kV
CR1-C1-C2 F2-FR2-PH60
Fire Resistant Cables
 
AlSECURE RHEYHALON-Security Cable JE-H(ST)HQH E30*
Wires and cables <1kV/Low smoke & fire resistant

Telecommunication Cable / Fire Alarm Cable

Cercuit Integrity 30 Minutes acc. to DIN 4102-12

Insulation Integrity FE180 acc. to IEC 60 331

Halogen Free with a better behaviour in case of fire acc. to DIN VDE 0815

 

 Наверх