English Вход Регистрация Каталог продукции Контакты
Глобальный эксперт в кабельных системах

О компании

Продукция и решения

Обслуживание

Работа в Nexans

Новости и пресса

Искать

RHEYFIRM NSSHCGEOEU-V 0.6/1 kV new

Закладка Печать Напишите нам
RHEYFIRM NSSHCGEOEU-V 0.6/1 kV new

Longwall / Coal cutter cable

Стандарты
Национальные  DIN VDE 0118; DIN VDE 0118-2; DIN VDE 0250 part 812
Описание

Application

For the connection of mobile machines under high mechanical loads, mainly mining applications, e.g. for coal cutting machines, particularly suitable for extreme bending loads inside of steel or plastic track chains. The phase-concentric monitoring shield and the common-concentric earth conductor, in conjunction with appropriate monitoring equipment, make it possible to monitor the cable for insulation faults and damage resulting from external influences. The cable can be delivered with 2, 3 or 6 pilot cores. 

 

Design

Phases cores

Conductor
Copper, tinned, extra flexible design

 Insulation

  • heat-resistant elastomeric insulation compound with extra high elongation break 
  • core screen, cold easy strip

 

Extensible Pilot cores

Conductor

special conductor capable of expansion and compression

Insulation

heat-resistant elastomeric insulation compound with extra high elongation break

 

Monitoring Conductor

Conductor

special conductor capable of expansion and compression, covering of semi-conducting rubber compound

 

Double layer inner sheath

  • semi-conducting layer
  • synthetic rubber compound

 

Reinforcement

concentric earth conductor as spinning of galvanized steel wire and copper strands

 

Outer sheath

Chlorinated, extra heavy duty mining rubber compound

 

Marking

Embossed marking e.g.:
RHEYFIRM NSSHCGEOEU-V 3x50/25KON+3x(ST+UEL) 0.6/1 kV  I NEXANS I  <vde>


 Наверх
Характеристики
Конструктивные характеристики
Материал жилы Tinned copper  
Concentric conductor Tinned copper wires  
Insulation Polyethylene/Petroleum Jelly  
Inner sheath Synthetic rubber  
Sheath colour Yellow  
Электрические характеристики
Rated Voltage Uo/U (Um) 0.6/1 kV  
Условия применения
Максимальная температура жилы в эксплуатации 90°C  
Limit surface temperature fixed installed -40 .. 80°C  
Limit surface temperature, flexible application -25 .. 80°C  
Oil resistance Yes  
Огнестойкость Yes  
Dynamic bending factor 2,5(xD)  

 Наверх
Связанная информация
RHEYFIRM NSSHCGEOEU-V 0.6/1 kV new   Letter code (30 kB)
RHEYFIRM NSSHCGEOEU-V 0.6/1 kV new   Electrical data (35 kB)

Nexans © все права защищены 2001 - 2012   Legal Notice | Контакты | Карта сайта